Get Quote
HomeAboutProductsSolutionsPartnersInsightsContact
Home/Products/Outdoor Cables/GYTA53 Armored Stranded Loose Tube Outdoor Fiber Optic Cable

GYTA53 Aluminum Tape Armored Stranded Loose Tube Direct Burial Cable

Armored stranded loose tube outdoor fiber optic cable with metallic central strength member (steel wire), APL moisture barrier, PSP/steel tape armor, and double PE sheath for duct and direct-buried routes.

Armored Stranded Loose Tube APL Moisture Barrier Double PE Sheath Metallic CSM
Configure GYTA53 CableSend RFQ by WhatsApp
GYTA53 Armored Stranded Loose Tube Outdoor Fiber Optic Cable
GYTA53 structure diagram

Product Overview

GYTA53 is an outdoor armored stranded loose tube fiber optic cable with a metallic central strength member (usually steel wire), APL moisture barrier, PSP / steel tape armor, and double PE sheath.

A typical structure includes stranded loose tubes around a metallic central strength member (usually steel wire), tube filling or water-blocking materials, APL moisture barrier, inner PE sheath, PSP / steel tape armor, and outer PE sheath. Fiber count, sheath material, armor structure, and mechanical performance should be confirmed according to final cable design and project requirements.

Request Quote Download Datasheet

Product Answer

What is GYTA53 fiber optic cable?
GYTA53 fiber optic cable is an outdoor armored stranded loose tube cable with a metallic central strength member (usually steel wire), an APL (aluminum-polyethylene laminated tape) moisture barrier, corrugated steel tape / PSP armor, and a double PE sheath. It is designed for direct burial, outdoor duct, feeder, and backbone routes where high mechanical protection against crush, rodents, and moisture ingress is required. MapleArashi manufactures GYTA53 cables with 4-144 fibers, G.652D or G.657 fiber types, and customizable sheath, armor, and water-blocking options based on project requirements.

Quick Selection Guide

Compare GYTA53 with other armored outdoor cables to select the right design for your project.

RequirementGYTA53 (APL + Steel Tape)GYTS53 (Steel Tape + Steel Wire)GYTY53 (Steel Tape + Steel Wire)GYFTY53 (FRP + Steel Tape)
Moisture barrierAPL tapeWater-blocking onlyWater-blocking onlyWater-blocking only
Central strength memberSteel wireSteel wireSteel wireFRP (non-metallic)
Armor typeSteel tape (PSP)Steel tape (PSP)Steel tape (PSP)Steel tape (PSP)
SheathDouble PEDouble PEDouble PEDouble PE
Best forDirect burial, high moistureDirect burial, ductBackbone & long-haulEMI-sensitive burial
EMI immunityPartial (metal CSM)Partial (metal CSM)Partial (metal CSM)Yes (non-metallic)
Best Pick★★★Direct burial with moistureDuct & general burialBackbone & long-haulEMI-sensitive burial

Key Takeaways

Citable Specification Notes

Product Structure

GYTA53 armored stranded loose tube fiber optic cable structure

GYTA53 armored stranded loose tube cable uses a multi-layer outdoor structure with APL moisture barrier, steel tape armor, and PE sheath protection for duct, underground, and demanding outdoor routes.

  • Stranded loose tube coreOptical fibers are placed in loose tubes stranded around a central strength member for stable backbone transmission.
  • Steel tape armorPSP / steel tape armor improves crush resistance and route protection for harsh installation environments.
  • Moisture barrier and PE sheathAPL moisture barrier and PE sheath provide outdoor environmental and moisture protection.
LayerComponentMaterial / Function
1Optical fiber unitSingle-mode fibers in stranded loose tubes according to project fiber count.
2Moisture barrierAPL aluminum-polyethylene laminated tape for moisture protection.
3ArmorSteel tape armor provides enhanced crush and mechanical protection.
4Outer sheathPE outer sheath provides outdoor environmental protection.

General Optical Performance

ItemTypical Value / OptionNotes
Fiber typeG.652D / G.657A1 / G.657A2Confirmed by project specification
Fiber count2-288 fibersSubject to final cable design
SheathPE / project-specified materialConfirmed by installation environment
ApplicationDuct / aerial / buried / distribution routeFinal use depends on route design
StandardIEC 60794 series referenceFinal test items confirmed before production

Key Features

Application Scenarios

Outdoor Duct Routes

Outdoor duct communication routes where armored protection and stranded loose tube structure are required.

Direct-Buried Projects

Routes requiring double sheath and armor protection, subject to project specification.

Backbone and Feeder Networks

Outdoor backbone and feeder routes in metro access and campus networks.

Industrial Communication Routes

Industrial and utility communication routes requiring enhanced mechanical protection.

GYTA53 is not designed for ADSS routes, messenger-style aerial routes, or indoor drop cable applications.

Model Comparison

Compare GYTA53 with similar armored and duct cable models to select the right cable for your project.

A5

GYTA53

Armored, Metallic CSM

  • CSM: Steel wire (metallic)
  • Moisture: APL aluminum tape
  • Armor: Steel tape + outer PE
  • Install: Direct burial, duct
  • Sheath: Double PE
Best for: Metallic armored direct burial
TA

GYTA

Metallic CSM, Non-Armored

  • CSM: Steel wire (metallic)
  • Moisture: APL aluminum tape
  • Armor: None
  • Install: Duct, outdoor
  • Sheath: Single PE
Best for: Standard outdoor duct with metallic CSM
FY

GYFTY53

Non-Metallic CSM, Armored

  • CSM: FRP (non-metallic)
  • Moisture: Water-blocking
  • Armor: Steel tape
  • Install: Duct, direct burial
  • Sheath: Double PE
Best for: Non-metallic CSM with armored protection
TS

GYTS

Steel Tape Armor, Non-APL

  • CSM: Steel / FRP
  • Moisture: Water-blocking
  • Armor: Steel tape
  • Install: Duct, outdoor
  • Sheath: Single PE
Best for: Duct with steel tape rodent protection

Why Choose MapleArashi for GYTA53 Fiber Optic Cable?

Project-Based Supply Support

GYTA53 cables are supplied through qualified production resources in China, with project-based quotation support and coordinated order fulfillment.

International Project Support

Fiber optic cable supply support for telecom operators, contractors, distributors, and project buyers in international markets.

Custom OEM/ODM Solutions

Flexible customization: fiber count, fiber type, armor type, sheath, drum length, packaging. OEM/ODM branding available.

Quality Control System

In-house tensile, bend, crush, water-blocking, and dimensional testing per IEC 60794 standards. Compliance documents available upon request.

Global Logistics Network

Standard FCL and LCL shipping from Shenzhen port. DDP and express logistics available for samples and small orders.

Dedicated Sales Support

One-on-one engineering support for product selection. Sample approval before mass production.

GYTA53 Cable Configurator

Configure the key requirement for GYTA53 Aluminum Tape Armored Stranded Loose Tube Direct Burial Cable. Select standard options or enter custom notes, then send your RFQ by WhatsApp or email.

FAQ About GYTA53 Armored Stranded Loose Tube Direct Burial Fiber Optic Cable

Q: What is GYTA53 fiber optic cable?
GYTA53 is an outdoor armored stranded loose tube fiber optic cable with a metallic central strength member (usually steel wire), an APL / aluminum-polyethylene laminated tape moisture barrier, corrugated steel tape / PSP armor, and double PE sheath. It is designed for direct burial, outdoor duct, and harsh mechanical environments.
Q: Is GYTA53 an all-dielectric cable?
No. GYTA53 contains a metallic central strength member (steel wire) plus metal armor (corrugated steel tape / PSP) and APL tape, so it should not be described as all-dielectric.
Q: What is the difference between GYTA and GYTA53?
GYTA is a stranded loose tube cable with APL moisture barrier and a single PE sheath for outdoor duct use. GYTA53 adds corrugated steel tape / PSP armor and an outer PE sheath, making it suitable for direct burial and harsh outdoor environments.
Q: What is the difference between GYTA53 and GYFTY53?
GYTA53 uses a metallic central strength member (steel wire) with an APL moisture barrier. GYFTY53 uses a non-metallic FRP central strength member without APL. Both have 53 armor structure (steel tape + double PE sheath).
Q: Can GYTA53 be used for direct burial?
GYTA53 is designed for duct and direct-buried outdoor routes when the final cable design and project specification confirm the required armor, sheath, tensile, crush, and environmental parameters.
Q: What should be confirmed before production?
Please confirm fiber count, fiber type, sheath material, armor structure, cable marking, drum length, installation route, mechanical requirements, and project standards.

Related Products

Technical Comparison

GYTA53 vs GYTS53 Fiber Optic Cable

Compare moisture-barrier layers, steel tape armor, double-sheath construction and direct-burial selection factors.

Read the comparison guide →